INPUTS
PWM input ranges
Sequencer triggers
Sequencer reset
Engine kill/parachute trigger
Engine kill/parachute trigger
OUTPUTS
Sequencer outputs
Sequencer outputs drive
Engine kill drive
Parachute drive
Servo supply voltage
Servo supply current
SUPPLY
Supply voltage range
Idle current consumption
Engine kill drive
Parachute drive
|
1 ms to 2 ms high, 50Hz
1.75 ms high
1.25 ms high
1.55 ms high
1.45 ms high
four 100ms pulses
2 A
-200 mA
1 A continuous, 3 A peak
5.5 V
3.3 A continuous
9 to 15 V
200 mA
-200 mA
1 A continuous, 3 A peak
|